Fire Safety in Warehouse
Warehouse fire safety is always a top priority by every company when it comes to setting up the most feasible warehouse environment. The companies usually prioritize compliance to fire codes and OSHA regulations. This compliance is a mandatory and preferential point when it comes to warehouse fire safety. But first it’s important to tally some of the misconceptions about warehouse fire safety.
- Fire inspection success results in validation to fire codes.
- The up-to-date validation to fire safety codes
- The warehouse with a sprinkler system guarantees the warehouse safety against sprinklers.
In order to keep the building safe from fires, its very much crucial to compliance with the fire safety codes. It aids in avoiding all sorts of potential destructive fire marshal fines.
Fire safety codes in warehouses
Fire suppression system in properly working condition: Having a properly installed and well maintained fire suppression system is a primary requirement for your warehouse.
Proper maintenance of distance beneath sprinkler heads: It’s very important to have the space of 18 inch below all sprinkler heads.
Space between pallets: It’s mandatory to store things on pallets kept at three inches of transverse space on every side of each pallet and six inches of longitudinal flue space between back-to-back rows. Flue space is the space between the loads but not between the pallets. This resembles that if you have a load above three inches off the side pallet, the flue space needs to be measured from that very point.
Warehouse fire safety tips
- Warehouse dead ends are respected and must not exceed 50 feet in length.
- In storage facilities with solid floors, aisle gaps should be created at least every 100 feet (100 feet).
- If the store touches a wall, place it within 50 feet (50 feet) of the wall. Basically, this means that the location of a solid stack floor must be within 50 feet of the aisle.
- If you manually replenish your inventory, make sure the aisle is at least 24 inches wide or half the width of the aisle, whichever is greater.
- Maintain at least 44 inches of unobstructed walkways during mechanical refills. Of course, smoking in the camp should never be allowed.
- Please post a “No Smoking” sign throughout the facility.
- Fire extinguisher is mandatory around the warehouse premises.
- Liquid propane fuel cylinders must be stored at least 20 feet away from emergency exits and are limited to £ 300 per storage location.
- When counting propane cylinders, keep in mind that the empty cylinders are full (just in case).
- If you need to store more fuel, make sure the storage locations are at least 300 feet apart.
Check your local Fire Service Act for guidelines related to:
- Automated material handling operations such as carousels and ASRS units
- Area for charging the battery
- plastic
- aerosol
- hazardous material

Sprinklers in Warehouse
By installing a sprinkler system in your warehouse, you can prevent business loss due to a fire. A rack sprinkler system in the warehouse can be used to prevent the spread of fire in certain rack storage areas. This will prevent the fire from spreading elsewhere in the camp. The Yingluck sprinkler system surrounds the rack structure and features a network of pipes that are centralized in a particular area.